- suitable for mounts that need a higher voltage of 24V (this cable is equipped with a connector for 10Micron GM1000 / GM2000)
- the Baader Planetarium Dual-Mode cable set allows you to use two PowerTanks to power those mounts which need 24V, in this case for professional mounts like a 10Micron
- The cable is custom-made and only available directly through Baader Planetarium
IMPORTANT NOTE FOR SAFE HANDLING OF 24V POWER SUPPLIES
The interconnection of two 12V power supplies always requires greater attention and care. This also applies to sharing two Celestron LiFePO4 Powertanks on 24V loads (e.g., GM1000 / GM 2000), using the Baader Dual Y cable for 10Micron 1000 and 2000 mounts.
Use as a 24V power supply is subject to the following conditions:
The two Celestron Powertanks used for this purpose:
- must not be made of one used and one newly purchased product - both power supplies must be the same age to use equivalent batteries
- must be used separately from one another, e.g. to power one separate 12V instrument. They must have similar age, number of load cycles, remaining power, etc.
- can only be charged separately at their respective loading device. Two power tanks on one loading device would damage the loading device because it does not have enough power for two batteries
- must only be used in the same charging state (ideally both powertanks should be charged fully at their own loading device before use), so that the protective electronics can work properly in every powertank
- should not be stored fully loaded or unloaded for an extended period of time (otherwise rapid aging may occur)
- must be interconnected only with the approved Baader-Y cable
- in case of strong aging or defect in one of the two powertanks (visible for example in a change in the charging behavior), do not connect the to units (if the batteries are unbalanced)
- must only be used for the intended mount. Other instruments or especially a short circuit at the power outlet could permanently damage the Powertank interconnection
- under all circumstances, the specifications of the individual powertanks must be respected in the interconnection; no higher power can be taken permanently, otherwise, this can lead to rapid aging of the powertanks.
In the case of non-observance, no guarantee can be given for the functional capability of these powertanks used for the 24V power supply. In the case of such negligence, permanent damage to the powertanks can not be ruled out. Liability for damage caused by improper handling of powertanks used in this way is excluded.